There are holes of .01 transmission in the filter every 5 bins.
The in band (.015 cm^-1 to .025 cm^-1) power from the source (no units): 0.464051
The out of band power from the source: 0.000403221
The in band (.015 cm^-1 to .025 cm^-1) power in ergs per second per centimeter squared due to the 300K filter is: 1983.47
The out of band power in ergs per second per centimeter squared due to the 300K filter is: 1320.35
The in band (.015 cm^-1 to .025 cm^-1) power in ergs per second per centimeter squared due to the 100K filter is: 0
The out of band power in ergs per second per centimeter squared due to the 100K filter is: 16.6971
The combined in band power from both the 300K and 100K filter is: 1983.47
The combined out of band power from both the 300K and 100K filter is: 1337.05
The load on the filter from the 300K blackbody in ergs per second per centimeter squared is: 584793
The load on the filter from the 100K blackbody in ergs per centimeter squared is: 8332.47
The load on the filter from both blackbodies in ergs per second per centimeter squared is: 593126
The fractional increase in the noise for the 300K filter is: 0.227447
The fractional increase in the noise for the 100K filter is: inf
The fractional increase in the noise for the both the 300 and 100K filters is: 0.23007
The polarimetric measurement error is: -3.21538e-05
The inband transmission is: 0.702
The fractional increase in the loading for the source is: 0.000868916
The fractional increase in the loading for the 300K filter is: 0.66568
The fractional increase in the loading for the 100K filter is: inf
The fractional increase in the loading for both filters is: 0.674098
Last updated September 7, 2000