SPARO Cabling



List of SPARO cables

Cables will run between two of the following points: SPARO, SPARO's Breakout Box in Control Room, VIPER's Breakout Box in Control Room, Pump Shack, and Data System Cabinet. Cabling is listed by endpoints. Number of cables are listed in perentheses.

SPARO to Data System Cabinet

SPARO to Pump Shack

SPARO to VIPER's Breakout Box in Control Room

  • SNOUT HEATER CABLE
  • SPARO to SPARO's Breakout Box in Control Room

    SPARO's Breakout Box in Control Room to Pump Shack

    Data System Cabinet to SPARO's Breakout Box in Control Room

    Data System Cabinet to VIPER's Breakout Box in Control Room

    Data System Cabinet to Pump Shack





    Specifications for SPARO Cables



    The specifications listed below are the cables that will be used to satisfy the requirements of SPARO's cabling. Some cables are already built and some cables will be built using existing VIPER cables. The rest will be ordered from Belden and the Belden catalog number is listed. All cables are PLENUM grade, TEFLON insulated wire with STRANDED TINNED COPPER conductors. All are FOIL SHIELDED and all but the 89418 and 88778 series are BRAID SHIELDED as well for additional interference screening and physical strength. The 88778 consists of INDIVIDUALLY SHIELDED TWISTED PAIRS.



    CABLE SPECS
    Cable Gage # conds Length Belden # Diam.(") Notes
    SIGNAL CABLES (2) 25 25ft ALREADY BUILT
    MOTOR CABLE 16 4 30ft 83704 not twisted pairs or shielded
    PREAMP POWER (2) 18 3 210ft 83653 0.191 (x2) BUILT
    STEPPER HEATER CABLE 18 4 89418 0.185 ALREADY BUILT, AT POLE, IN VIPER CABLE WRAP
    VALVE HEATER CABLE 18 4 89418 0.185 ALREADY BUILT, AT POLE, IN VIPER CABLE WRAP
    He-3 PRESSURE CABLES (2) 22 3 230ft 83553 0.150 (x2) BUILT
    CYCLING/SENSING CABLE 22 22(11) 230ft 88778 0.306(x2) BUILT
    PREAMP HEAT (2) 18 4 (x2) 460ft 89418 0.185 (x2)(x2) 2 4-cond cables coupled
    He-4 PRESSURE CABLE 22 6 45ft 83556 0.185 BUILT
    MOTOR SERIAL CABLE* 20 4 115ft 83604 0.180 BUILT
    GAIN CONTROL CABLE 20 4 115ft 83604 0.180 BUILT
    OPTICAL FIBERS (2) ALREADY BUILT
    DATA SYS CABINET HEATER 18 4 89418 0.185 ALREADY BUILT, AT POLE, IN VIPER CABLE WRAP
    DATA SYS POWER (Digital) 16 2 115ft 83702 0.200 BUILT
    DATA SYS POWER (Analog) 16 3 115ft 83703 0.221 BUILT
    Total Diam. 0.90" This is calculated for all cables through SPARO's cable wrap. Excludes STEPPER HEATER, VALVE HEATER. and DATA SYS CABINET HEATER CABLES. Also excludes MOTOR and SIGNAL CABLES and He-4 PRESSURE CABLE. Calculated by summing cross sectional areas and finding the diameter of a circle of this area.

    * - Motor Serial Cable is using the 18-4 conductor wire because the 3 conductor cable is not available.


    SPARO Requirements of VIPER Leftover Cabling
    Belden # Gage # conds Length Needed (Length with spare)
    88778 22 22(11) 460ft(710ft)


    Cabling to be Ordered for SPARO
    Belden # Gage # conds Length* Price/ft Price Notes
    83702 16 2 125ft $1.30 $162.50 spare comes from 83703
    83703 16 3 245ft $1.26 $308.70 Spare used for 16-2 or 16-3 cables
    83704 16 4 55ft $1.44 $79.20 NOT PAIRED OR TWISTED
    83653 18 3 225ft $1.12 $252.00 Spare comes from extra 89418 if needed
    89418 18 4 815ft $0.92 $749.80 spare used to construct extra 83653
    83604 20 4 360ft $0.97 $349.20 Motor Serial Cable using 4 cond because no 3 available
    83556 22 6 50ft $1.01 $50.50 spare comes from 83553
    83553 22 3 450ft $0.44 $198.00 Extra cable can construct 83556 or 83553
    Total Cost $2149.90

    * - Length includes spare cabling in case extra cables need to be built.